| Color: |
White, Oyster, and Gray |
Tensile:
ASTM D-412
Strength:
Elongation:
Permanent Set at Break: |
2,200 psi Min. (155 kg/m2)
350% Min.
Less than 20% |
| Tear Resistance: |
ASTM D-624 Die C 280 Lb/In (50 kg/cm) |
| Hardness Cured |
ASTM D-676 80 ± 5 Shore A |
| Water Vapor Permeability: |
ASTM E-96 Method B, 100% R.H. Difference
0.02 Perm Inches (.5 mm) |
| Flammability: |
ASTM E-108 (UL790) Class A |
| Toxicity |
Contains flammable solvents and an isocyanate prepolymer. Threshold limit is 100 parts solvent vapor per 1 million parts air. Use only in ventilated areas or with fresh air supplied face masks if in a confined area. Avoid breathing vapors or spray mist. Contains an isocyanate polymer, which may be irritating to the skin or toxic if inhaled. Any material contacting skin should be neutralized by washing with generous quantities of soap and water. |
| Adhesion: |
Excellent adhesion to polyurethane foam, single ply, metal, and other surfaces. Some surfaces may require bonding primer |
| Coverage: |
Sq.ft./Gal./Mil. 1128 Minimum (21 m2/L/mm) |
Solids:
(Method 4041 Fed. Std. 141) |
Weight: 79.1% Minimum
Volume: 70.3% Minimum |
| V.O.C.: |
Maximum volatile organic compounds content is 255 grams per liter. |
| Flash Point: |
ASTM D-56 65ºF (18ºC) |
| Storage Stability: |
Black 6 months and colors 3 months from date of manufacture when stored in sealed containers below 75ºF (24ºC). U-6801 is produced on a "by order" only, allow time for production when ordering. |
| Thinner & Cleaner: |
Use T-5116 |
| Cure: |
Applied coating will cure in 24 hours with 70ºF (21ºC) and 40% relative humidity. Lower temperatures and humidity will require longer times to cure. |
| Clean Up: |
Clean spray equipment with T-5130 thinner. |